成年美女黄网站色大免费视频-国产猛男猛女超爽免费视频-亚洲精品国产精品国自产小说-亚洲欧美日韩中文加勒比

咨詢熱線:021-80392549
發(fā)布信息

賀德克溫度開關(guān) ETS 3200 溫度開關(guān)

點(diǎn)擊圖片查看原圖
品牌: 賀德克溫度傳感器
單價(jià): 面議
所在地: 上海
有效期至: 長期有效
最后更新: 2024-06-09 12:13
瀏覽次數(shù): 909
詢價(jià)
店鋪基本資料信息
 
產(chǎn)品詳細(xì)說明

ETS 3200是一款具有數(shù)字顯示的緊湊型電子溫度開關(guān)。

憑借其集成的溫度探頭,ETS 3200特別適合直接油箱安裝,并有多種長度可供選擇。

具有一個(gè)或兩個(gè)開關(guān)輸出和可選的附加模擬輸出信號的不同輸出版本,提供了多種應(yīng)用可能性。

使用按鍵板可以非?焖俸洼p松地調(diào)整開關(guān)點(diǎn)和相關(guān)的滯后。

Specifications

Type

Electronic Temperature Switch

Model Code Description

ETS 3226-2-018-000

Direct Current (DC) Supply Voltage When Applied According to UL Specifications (Without Analog Output)

9 to 35 V

Note for Direct Current (DC) Supply Voltage When Applied According to UL Specifications

Limited energy - According to 9.3 UL 61010; Class 2; UL 1310/1585; LPS UL 60950

Maximum Current Consumption (With Inactive Switching Output)

35 mA

Maximum Current Consumption (With Inactive Switching Output and Analog Output)

55 mA

Display

4-Digit, LED, 7 Segment, Red, Height of Digits 7 mm

Weight

~135 g

Material of Connection

Stainless Steel

Seal Material

Fluoroelastomer (FKM)

Maximum Output Permitted Load Resistance

500

Minimum Output Permitted Load Resistance

1 k

Switching Function

Switching direction of the switching outputs adjustable (N/C or N/O)

Electrical Connection

Male M12x1, 4 Pole

CUL®US Mark

Certificate No.: E318391

Note for CUL®US Mark

Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No. 61010-1

Switch Point

-23 to 100 ºC-9 to 212 ºF

Hysteresis (Switch Point)

1.0 to 123.5 ºC2 to 222 ºF

Residual Ripple of Supply Voltage

≤ 5 %

Increment (Switch Point)

0.5 ºC1.0 ºF

Note for Increment (Switch Point, Window Function)

 
All ranges given in the table can be adjusted by the increments shown.

Lower Switch Value (Window Function)

-23 to 97.5 ºC-9 to 208 ºF

Upper Switch Value (Window Function)

-22 to 98.5 ºC-7 to 209 ºF

Increment (Window Function)

0.5 ºC1.0 ºF

Maximum Total Current Consumption

2.455 A

Modification Number

000

Switching Outputs

2 Switching Outputs

Division

17

BUn

EA

Input Data

Measuring Range

-25 to 100 ºC-13 to 212 ºF

Input Probe Length

0.71 in18 mm

Input Pressure Resistance

8700 psi

Input Mechanical Connection

G1/2 A DIN 3852 (Male)

Torque Value

45 N·m33 lb·ft

Input Mechanical Connection Type

G1/2 A DIN 3852, Male

Input Mechanical Connection Size

G1/2, Male

Output Data

Accuracy at Room Temperature

≤ ± 2.0ºF (+/- 1.0ºC)

Operating Temperature [Min]

-25 ºC-13 ºF

Operating Temperature [Max]

100 ºC212 ºF

Output Temperature Drift at Maximum Zero Point and Range (Full Scale)

≤ ± 0.0085% %/°F

Switch Outputs

Switch Outputs Type

PNP Transistor Switching Output

Maximum Switching Current Per Switch Output

1.2 A

Switching Cycles In Million

> 100 million

Rise Time to DIN EN 60751 for t50

3 s

Rise Time to DIN EN 60751 for t80

9 s

Environmental Conditions

Ambient Temperature Range

-13 to 140 ºF

Ambient Temperature Range

-13 to 176 ºF

Sensing Temperature [Max]

100 ºC212 ºF

Sensing Temperature [Min]

-25 ºC-13 ºF

Storage temperature range

-40 to 176 ºF

Fluid temperature range

-13 to 212 ºF

Note for Fluid Temperature Range

-13 °F with FPM seal, -40 ºF on request

CE Mark

CE Mark EN 61000-6-1/2/3/4

Vibration Resistance According to DIN EN 60068-2-6 at 0 to 500 Hz

≤ 10 g

Shock Resistance According to DIN EN 60068-2-29 (11 ms)

≤ 50 g

Protection class to IEC 6529

IP 67

Pin Connections

Pin Connection 1

+UB

Pin Connection 2

SP2

Pin Connection 3

0 Voltage

Pin Connection 4

SP1

Dimensions

Sensor Diameter

6 mm

Sensor Length

18 mm

Length

42 mm

Width

40.4 mm

Setting Options

All the settings available on the ETS 3200 are combined in 2 easy-to navigate menus. To prevent unauthorized adjustment of the instrument, a programming lock can be set.

Additional Information

For optimum adaptation to the particular application, the instrument has many additional adjustment parameters (e.g. switching delay times, N/C / N/O function, etc.).

Accessories

Appropriate accessories, such as electrical connectors, protective sleeves for tank mounting, splash guards, etc. can be found in the Accessories brochure.

Special Features

 

  • 2 switching outputs, up to 1.2 A load per output.
  • Optional analog output signal selectable (4 .. 20 mA, 0 .. 10 V)
  • 4-digit display
  • Optimum alignment - display can be rotated in two planes (axes)
  • Switching / switch-back points and many useful additional functions can be set using the keypad.
  • Display of temperature and unit of measurement in ºC or ºF
  • Switching mode of the switching outputs adjustable (switching point function or window function)
  • Switching direction of the switching outputs adjustable (N/C or N/O)
  • Switch-on and switch-off delay adjustable from 0.00 .. 99.99 seconds
  • Choice of display (actual temperature, peak temperature, switching point 1, switching point 2, display off)

 

Note

Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.

Subject to technical modifications.

更多賀德克產(chǎn)品請咨詢賀德克電氣服務(wù)商http://hydac.gongboshi.com/